PRIME
|
|
·
High-resolution one
dimensional patented linear piezo drive. ·
Single and multiple pulse
modes. ·
Compatible with many
3-axis micromanipulators · Facilitates penetration of tough oolemma membranes maximising oocyte survival |
|
The Prime Tech PMM-150FU uses the piezoelectric effect to generate linear vibrations of a micropipette holder in contact with the piezo element. The finely controlled ‘stabbing’ motion of the micropipette assists penetration in otherwise difficult microinjection applications, reducing distortion of the oocyte membrane. This limits trauma to the oocyte and ensures best possible survival rate following injection. Since Prime Tech introduced its first piezo impact micromanipulation system in 1990 the company has been at forefront in producing and developing systems involving this technique. The PMM has now become the system of choice for applications such as mouse nuclear transfer, ICSI and blastocyst injection. In operation the drive unit itself (MB-U) is mounted to a suitable 3-axis micromanipulator. The standard AD-NE adaptor permits the unit to be mounted to most Narishige illumination support mounting hydraulic micromanipulators. Other adaptors are available as accessories. |
MB-U Drive Unit Controls on the OP-15 operation box enable two sets of speed and intensity conditions to be selected including single and multiple pulse modes. The user can toggle between these two condition sets from the operation box or using the footswitch provided. |
|
|
|




AD-BXW Option. For Sutter’s XenoWorks micromanipulator.
NOTE: For mounting the MB-U to Eppendorf’s TransferMan NK2 or PatchMan NP2 an
Eppendorf X-Y Extension plate is required. This is Eppendorf part no.
5181 236.002
SPECIFICATIONS PMM-150FU
|
CONTROLLER |
Single output (controls 1 MB-U unit) |
|
(MB-U) |
Movement range: approx. + 5mm Maximum speed: 0.08mm/s Resolution: approx. 0.1μm |
|
OPERATION BOX |
Adjustment dials: 2 sets (Speed 16 levels, intensity 16 levels) Indicator lamps: Condition A (green) Condition B (yellow) Selection Switch: A – B Movement keys: Left and/or Right |
|
FOOTSWITCH |
Left pedal: moves to left only Right pedal: Selects condition A or B |
|
DIMENSIONS & WEIGHT CONTROLLER OPERATION BOX «MB-U» / IMPACT UNIT «MB-U» SLIDE BASE UNIT FOOTSWITCH |
240(W) x 340(D) x 140(H) mm Weight approx. 5.0kg 100(W) x 160(D) x 60(H) mm Weight approx. 530g (including cable) 125g (including cable) 75g 145(W) x 140(D) x 38(H)mm Weight approx. 820g (including cable)
|
|
OPERATING TEMP. |
5 ~ 40°C (Avoid high humidity) |
|
POWER |
AC100 ~ 240v, 50/60Hz, 60VA |
|
ACCESSORIES |
Power cord, Spare fuse |

·
Precise manual operation
·
Excellent sensitivity controllability and
reliability
· Compact
The PrimeTech HDJ-M3 microinjector is
recommended for use with the PMM-150FU ensuring maximum sensitivity and
optimised performance during micromanipulation.
The HDJ-M3 allows injection of spermatozoa, DNA and/or other solutions
into somatic cells, unfertilised eggs and embryos.
Specifications |
|
|
Accessories included |
IH-3 injection holder 4mm o.d. for use with 1mm o.d. capillaries Teflon tube 1m (2mm o.d) Teflon Luer connector (2) Silicon tube 6mm (20) |
|
Dimensions (mm) |
70 x 182.5 x 90 (WxDxH) |
|
Weight |
880g |
|
Syringe capacity |
9ml |
|
Volume per turn |
3.9μl |
|
Screw stroke |
20mm |
When the HDJ-M3 is combined with the PMM-150FU the system is known as the PMM-150HJ. The PMM-150FU may also be used in conjunction with other microinjectors such as Eppendorf’s CellTram or Narishige syringe-type injectors IM-9B or IM-6.
|
|
|
PMM-150FU |
Piezo Impact Drive System comprising: MB-U piezo impact drive unit (includes IH-3 injection unit) PMAS-CTI50 Controller OP-15 Operation box OP-14 Footswitch AD-NE mounting adaptor (Narishige type) Operating manual |
PMM-150HJ |
Piezo Impact Drive System as above but including HDJ-M3 manual injector |
ADAPTORSAD-NE AD-NSL AD-LBK AD-BXW |
(Standard) Narishige type for Narishige stage mount for Leica. Universal joint type for Sutter Xenoworks |
INJECTORHDJ-M3 |
Manual microinjector including IH-3 injector holder, tubing, connectors and operating manual |
PARTSIH-3 OTI-SS1 OCT-SF10 OCT-EPC |
Injection Holder, for 1mm o.d. glass capillary and 2mm o.d. Teflon tube. Spacer set for IH-3 including spacer (1) and silicone tube (2 x 50mm). Tubing set for IH-3 (1m Teflon tube 2mm o.d. and Teflon Luer connectors 2). Supplied as standard with HDJ-M3. Note: If you will use the Xenoworks microinjector this tubing set will be needed. Tubing set for Eppendorf CellTram (1m Teflon tube 2mm o.d., Teflon Luer connector and SUS connector for CellTram) |